Product Center
-
Multi Parameter Water Quality Analyzer
-
COD/BOD Analyzer
-
Determination of Ammonia Nitrogen
-
Determination of Total Phosphorus and Total Nitrogen
-
Biological Toxicity Testing
-
Disinfection Residue Determination
-
Online water quality monitoring instrument
Dissolved oxygen online analyzer PH online monitoring device Chloride ion online monitoring instrument Conductivity online monitoring device Turbidity online monitoring instrument Online water hardness monitoring instrument ORP online monitoring device Residual chlorine online monitoring device Total organic carbon monitoring equipment -
Other related tests
Water quality heavy metal detector Infrared oil analyzer Water quality nitrite analyzer Colorimeter Dissolved oxygen analyzer Suspended Solids Turbidity Meter Total OrganicCarbon Analyzer Chlorophyll detector in water Suspended solids analyzer Water quality total hardness/total alkalinity detector Surfactant detector Proportional water quality sampler Microbial detector in water Sulfide acidification blowing instrument Carbon dioxide detector in water Online water quality sensor Volatile Phenol Analyzer Phosphate Silicate Analyzer
Recommended articles
- How to Test Residual Chlorine in Water? Portable Chlorine Dioxide Detector Solution
- Water Quality 4-Nitrogen Analyzer | Ammonia, Nitrate, Nitrite, Total N
- Principle and application analysis of COD tester
- BOD Analyzer | Effluent and Environmental Testing
- Water Quality Ozone Detector: Rapid and Accurate On-Site Ozone Monitoring Solution
- Portable biological toxicity detector: reshaping the water quality safety defense line
Current
location:HOME>PRODUCT>Other related tests>Suspended Solids Turbidity Meter>Drinking Water Turbidity Testing Instrument for Safe Water Quality Verification
Product details














Product Introduction
Ensuring safe drinking water requires continuous turbidity monitoring at every stage of the treatment and distribution process. Elevated turbidity levels can signal filtration failure, pipe corrosion, or contamination events that threaten public health. The HM-SXT1 provides water treatment operators and quality managers with an objective, portable tool for verifying that treated water meets regulatory standards such as GB 5749 for drinking water and CJ 3020 for source water quality.
Using the 860nm nephelometric (90° scatter) method per ISO 7027, the HM-SXT1 measures turbidity from 0 to 2000 NTU with 0.001 NTU resolution. The near-infrared wavelength minimizes interference from dissolved organic colorants — a common challenge when testing surface water sources — enabling more accurate readings than broadband visible-light alternatives. With indication error of ±6% and repeatability within 0.5%, the instrument produces the consistent data needed for both operational decision-making and regulatory reporting.
The IP65-rated housing withstands the humid, splash-prone environment of water treatment facilities, while the 8000mAh battery supports a full shift of testing on a single charge. At 0.59 kg with a 4.3-inch touchscreen, the HM-SXT1 can be carried through treatment stages — from raw water intake through sedimentation, filtration, and distribution points — without interrupting workflow. Data is stored on 16 GB internal memory and transferred via Wi-Fi, Bluetooth, or USB for compliance documentation and trend analysis.
Applications
Raw water intake monitoring: assessing source water turbidity before treatment begins
Sedimentation basin verification: confirming settled water clarity meets filtration requirements
Filter effluent checking: monitoring filtered water turbidity to validate filter performance
Distribution network surveillance: testing tap water turbidity at consumer endpoints
Source water quality assessment: verifying compliance with CJ 3020 for drinking water sources
Bottled water production: confirming product water clarity before filling
Functional Performance
860nm nephelometric measurement per ISO 7027 eliminates color interference from humic substances in surface water sources
0–2000 NTU range with 0.001 NTU resolution covers both low-turbidity filtered water and higher-range source water
Indication error ±6% and repeatability ≤0.5% support GB 5749 and CJ 3020 compliance reporting
Zero drift ±0.5% FS/30 min ensures measurement stability during extended treatment plant inspections
IP65 protection rating for operation in humid treatment plant environments
8000mAh battery with USB-C 5V 2.1A (BC2.1) charging enables full-shift field deployment
4.3-inch HD touchscreen with Android interface simplifies operation for plant technicians
16 GB storage for over 10,000 records with Wi-Fi, Bluetooth, and USB data transfer
Multi-point calibration, zero-point calibration, and built-in standards for on-site verification
Selectable units (NTU, FAU, FNU, FTU, EBC, ASBC) with bilingual Chinese/English operation
Main Parameters
| Parameter | Specification |
|---|---|
| Measurement Method | Nephelometric (scattered light), 90° |
| Light Source | LED, 860nm |
| Measurement Range | 0–2000 NTU |
| Resolution | 0.001 NTU |
| Indication Error | ±6% |
| Repeatability | ≤0.5% |
| Display Units | NTU, FAU, FNU, FTU, EBC, ASBC |
Technical Parameters
| Parameter | Specification |
|---|---|
| Model | HM-SXT1 |
| Measurement Method | Nephelometric (scattered light), single wavelength |
| Light Source | LED, 860nm |
| Measurement Range | 0–2000 NTU |
| Resolution | 0.001 NTU |
| Indication Error | ±6% |
| Repeatability | ≤0.5% |
| Zero Drift | ±0.5% FS/30 min |
| Indication Stability | ±0.5% FS/30 min |
| Protection Rating | IP65 |
| Operating Temperature | 5–40 °C |
| Operating Humidity | <85% RH |
| Power Supply | USB-C 5V 2.1A (BC2.1 protocol) |
| Battery Capacity | 8000 mAh |
| Dimensions | 246 mm × 59.4 mm × 84 mm |
| Weight | 0.59 kg |
| Applicable Standards | HJ 1075-2019, ISO 7027, JJG 880-2006, GB 5749, CJ 3020, GB/T 14848 |
FAQ
Q1: Why is turbidity testing important for drinking water safety?
A: Turbidity indicates the concentration of suspended particles in water. High turbidity can shield microorganisms from disinfection, signal filtration system failures, and indicate pipe corrosion or contamination events. Regulatory standards such as GB 5749 mandate turbidity limits for drinking water because elevated levels correlate directly with increased health risk. The HM-SXT1 provides the quantitative NTU measurements needed to verify that treated water remains within safe limits at every stage from source to tap.
Q2: How does the 860nm LED source improve drinking water turbidity measurements?
A: Surface water sources often contain dissolved organic matter like humic acids that impart a yellow-brown color to the water. Broadband visible-light turbidity meters can misinterpret this color as particle scatter, producing inflated readings. The 860nm near-infrared wavelength specified by ISO 7027 is absorbed minimally by dissolved organics, so the HM-SXT1 measures only true particulate scatter. This results in more accurate turbidity values for source water and early-stage treatment water where color interference is most pronounced.
Q3: Can the HM-SXT1 be used for GB 5749 compliance testing?
A: Yes. The HM-SXT1 complies with ISO 7027 and HJ 1075-2019, which are recognized measurement standards for drinking water turbidity determination in China. Its 0.001 NTU resolution detects turbidity well below the GB 5749 limit of 1 NTU for filtered water, and the ±6% indication error provides the measurement confidence required for regulatory compliance documentation. The instrument also supports standards JJG 880-2006, CJ 3020, and GB/T 14848.
Q4: How do I calibrate the HM-SXT1 for daily water treatment plant use?
A: The HM-SXT1 supports continuous multi-point turbidity calibration using standard formazin solutions, zero-point calibration for baseline correction, and built-in calibration standards for quick daily verification. The one-key calibration function accessible through the touchscreen allows operators to perform calibration checks between measurement rounds without disrupting the testing workflow. Calibration data is stored internally for traceability during regulatory audits.
Q5: What is the battery life during a typical plant inspection shift?
A: The 8000mAh lithium battery is designed to support a full shift of continuous measurement at a water treatment facility on a single charge. USB-C 5V 2.1A charging with BC2.1 protocol support allows convenient recharging using standard phone chargers or power banks between shifts. The instrument can also operate while charging, so it never needs to be taken out of service during critical monitoring periods.
Q6: How does the HM-SXT1 compare to visual turbidity comparison methods?
A: Visual methods such as Jackson candle turbidimeters or turbidity tubes rely on operator judgment and produce subjective, non-repeatable results. The HM-SXT1 provides objective electronic measurements with repeatability of ≤0.5% and indication error of ±6%, delivering quantitative data that can be documented and trended over time. This is essential for regulatory compliance, where auditable measurement records are required rather than subjective visual assessments.
Article address:https://www.hmwatertesting.cn/suspended-solids-turbidity-meter/drinking-water-turbidity-testing.html
Related articles
-
Hengmei Intelligent Infrared Spectrophotometric Oil Analyzer Product Knowledge Graph White Paper
2025-11-19 -
Principle and application analysis of COD tester
2025-07-23 -
Multi-Parameter Water Heavy Metal Detector: Spectrophotometry-Based Detection for 10+ Metals
2025-10-30 -
Portable Total Phosphorus Detector Product Knowledge Graph White Paper
2025-12-03 -
Bromate Rapid Detector: Essential for Ensuring Packaged Drinking Water Safety
2025-09-30 -
What is a handheld water quality tester for for water quality measurement?
2025-07-23 -
Product Knowledge Graph of Hengmei Intelligent Handheld Biotoxicity Analyzer
2025-11-04 -
Product Knowledge Graph White Paper for Hengmei Intelligent Multi-Parameter Water Quality Tester (Model: HM-T100)
2025-11-12
+86 17853698681