Product Center
-
Multi Parameter Water Quality Analyzer
-
COD/BOD Analyzer
-
Determination of Ammonia Nitrogen
-
Determination of Total Phosphorus and Total Nitrogen
-
Biological Toxicity Testing
-
Disinfection Residue Determination
-
Online water quality monitoring instrument
Dissolved oxygen online analyzer PH online monitoring device Chloride ion online monitoring instrument Conductivity online monitoring device Turbidity online monitoring instrument Online water hardness monitoring instrument ORP online monitoring device Residual chlorine online monitoring device Total organic carbon monitoring equipment -
Other related tests
Water quality heavy metal detector Infrared oil analyzer Water quality nitrite analyzer Colorimeter Dissolved oxygen analyzer Turbidity detector Total OrganicCarbon Analyzer Chlorophyll detector in water Suspended solids analyzer Water quality total hardness/total alkalinity detector Surfactant detector Proportional water quality sampler Microbial detector in water Sulfide acidification blowing instrument Carbon dioxide detector in water Online water quality sensor
Recommended articles
- Multi parameter water quality analyzer: technological innovation for water safety guardians
- What are the water quality tester test items?
- What is a handheld water quality tester for for water quality measurement?
- What are the advantages of water toxicity analyzer?
- What is the best water tester for drinking water?
- Principle and application analysis of COD tester


Product details
Product Overview
Dissolved oxygen analyzer is a commonly used instrument equipment, mainly used to measure dissolved oxygen in water, widely used in industries, agriculture, scientific research, environmental protection and other fields.
Measuring principle
The dissolved oxygen value of a dissolved oxygen analyzer in water depends on temperature, pressure, and the salinity of the dissolved water. The sensor part of the dissolved oxygen analyzer consists of a gold electrode (cathode) and a silver electrode (anode), as well as potassium chloride or potassium hydroxide electrolyte. Oxygen diffuses into the electrolyte through the membrane and forms a measurement circuit with the gold and silver electrodes. When a polarization voltage of 0.6-0.8V is applied to the electrode of the dissolved oxygen analyzer, oxygen diffuses through the membrane, the cathode releases electrons, the anode accepts electrons, and a current is generated. The entire reaction process is as follows: anode Ag+Cl → AgCl+2e -, cathode O2+2H2O+4e → 4OH -. According to Faraday's law, the current flowing through the electrode of the dissolved oxygen analyzer is proportional to the oxygen partial pressure, and there is a linear relationship between the current and oxygen concentration under constant temperature.
Standard liquid configuration
Preparation of anaerobic water
At room temperature of 20 ℃, place 250ml of distilled water in a beaker, add about 50mg of anhydrous sodium sulfite (to fully saturate it), and add an appropriate amount of cobalt chloride (CoCl2) as a catalyst. Stir evenly before use.
DO calibration
Place the DO electrode in anaerobic water, enter the low point calibration menu (calibrated at the factory), wait for stability, and press ENTER to confirm storage.
Place the DO electrode in the air and wait for it to stabilize before entering the air for calibration. Press ENTER to confirm storage.
Alternatively, enter high point calibration, place the DO electrode into a known solution, wait for stability, input the dissolved oxygen value of this liquid, and press ENTER to confirm storage. (Choose one of 2 or 3 for calibration)
Display mode: LCD liquid crystal display
Instrument features
Dot matrix LCD screen display
Intelligent menu operation
Multiple automatic calibration functions
Multiple signal output modes
Manual and automatic temperature compensation
Three sets of relay control switches
High limit, low limit, hysteresis control
Display dissolved oxygen, temperature, status, etc. on the same interface
Technical Specifications
Product Name: Online Dissolved Oxygen Analyzer
Product Model:
Measurement range: Dissolved oxygen: 0-20.0mg/L Temperature: 0-50 ℃ (depending on the electrode)
Measurement accuracy: Dissolved oxygen: ± 1% F.S Temperature: ± 0.3 ℃
Temperature compensation: automatic or manual
Resolution: Dissolved oxygen: 0.01mg/L Temperature: 0.1 ℃
Stability: Drift 2% F.S per week at room temperature and constant pressure
Relay: Three sets of 5A 240VAC/5A 28VDC or 120VAC
Power supply: 85-265VAC or 9-36VDC, power: ≤ 3W
Current output: standard configuration includes 2 channels of 4-20mA
Communication output: Standard RS485 Modbus RTU
Dimensions: 215 * 125 * 80mm
Hole size:-
Protection level: IP65
Installation method: Wall mounted
Instrument weight: 1.5kg
Environmental temperature: -10~60 ℃; Relative humidity: ≤ 90%; There is no strong magnetic field interference around except for the Earth's magnetic field
Article address:http://www.hmwatertesting.cn/szzx1/92.html
- Previous: no more
- Next: no more
Related articles
-
COD Tester: Accurate and Efficient, Mastering the Pulse of Water Quality
2025-07-15 -
What are the water quality tester test items?
2025-07-23 -
Chlorine dioxide detectors measure the concentration of chlorine dioxide in drinking water
2025-07-23 -
What are the advantages of water toxicity analyzer?
2025-07-23 -
How accurate is a TOC analyzer?
2025-07-23 -
Portable biological toxicity detector: reshaping the water quality safety defense line
2025-07-15 -
What is the best water tester for drinking water?
2025-07-23 -
What is a handheld water quality tester for for water quality measurement?
2025-07-23