Product Center
-
Multi Parameter Water Quality Analyzer
-
COD/BOD Analyzer
-
Determination of Ammonia Nitrogen
-
Determination of Total Phosphorus and Total Nitrogen
-
Biological Toxicity Testing
-
Disinfection Residue Determination
-
Online water quality monitoring instrument
Dissolved oxygen online analyzer PH online monitoring device Chloride ion online monitoring instrument Conductivity online monitoring device Turbidity online monitoring instrument Online water hardness monitoring instrument ORP online monitoring device Residual chlorine online monitoring device Total organic carbon monitoring equipment -
Other related tests
Water quality heavy metal detector Infrared oil analyzer Water quality nitrite analyzer Colorimeter Dissolved oxygen analyzer Turbidity detector Total OrganicCarbon Analyzer Chlorophyll detector in water Suspended solids analyzer Water quality total hardness/total alkalinity detector Surfactant detector Proportional water quality sampler Microbial detector in water Sulfide acidification blowing instrument Carbon dioxide detector in water Online water quality sensor
Recommended articles
- BOD meter for biological oxygen demand testing: principles, advantages and applications
- Portable Infrared Spectrophotometer for Oil Analysis: Rapid On-Site Detection of Water and Soil Oil Pollution
- Portable biological toxicity detector: reshaping the water quality safety defense line
- What is a handheld water quality tester for for water quality measurement?
- Water Quality Ozone Detector: Rapid and Accurate On-Site Ozone Monitoring Solution
- Principle and application analysis of COD tester


Product details
Product Overview:
The residual chlorine online monitoring instrument is a brand new residual chlorine analyzer with high intelligence and flexibility, which can simultaneously measure residual chlorine and hypochlorous acid, pH、 Temperature is widely used in industries such as power, water supply, medicine, chemical, and food to continuously measure residual chlorine and pH values in water.
Product Features:
Features such as full intelligence, multifunctionality, high measurement performance, and strong environmental adaptability;
Simultaneous display of multiple parameters, including residual chlorine value, output current, and time;
4-20mA transmission output, relay high and low alarm control output, RS485 communication output and other variable outputs, system intelligent control;
Using two-point calibration method can correct sensor errors;
Adapt to various types of measuring electrodes;
High precision automatic temperature compensation system;
Chinese and English operation interface
Composition system:
Online transmitter/host (LCD menu in Chinese and English)
Immersion and flow-through electrodes/sensors
10 meter cable (standard, extension to be discussed separately)
4-20mA/RS485 can be connected to PLC or recorder, etc. (RS485 needs to be purchased)
Immersion installation bracket, circulation accessories, outdoor instrument box (to be purchased)
Features:
Dot matrix LCD screen display
Intelligent menu operation
Multiple automatic calibration functions
Multiple signal output modes
Manual and automatic temperature compensation
Three sets of relay control switches
High limit, low limit, hysteresis control
Display residual chlorine, temperature, status, etc. on the same interface
Technical Specifications:
Product Name: Online Residual Chlorine Analyzer
Product model: HM-SYL
Measurement range: Flow type: 0.05-20.00mg/L (ppm) Temperature: 0-50 ℃
Measurement accuracy: ± 1% F.S Temperature: ± 0.3 ℃
Temperature compensation: automatic or manual
Resolution: 0.001mg/L Temperature: 0.1 ℃
Response time: 90% less than 90 seconds
Relay: Three sets of 5A 240VAC/5A 28VDC or 120VAC
Power supply: 85-265VAC or 9-36VDC, power: ≤ 3W
Current output: standard configuration includes 2 channels of 4-20mA
Communication output: Standard RS485 Modbus RTU
Dimensions: 215 * 125 * 80mm
Hole size:-
Protection level: IP65
Installation method: Wall mounted
Instrument weight: 1.5kg
Environmental temperature: -10~60 ℃; Relative humidity: ≤ 90%; There is no strong magnetic field interference around except for the Earth's magnetic field
Article address:http://www.hmwatertesting.cn/szzx8/99.html
- Previous: no more
- Next: no more
Related articles
-
BOD meter for biological oxygen demand testing: principles, advantages and applications
2025-07-23 -
Principle and application analysis of COD tester
2025-07-23 -
Portable biological toxicity detector: reshaping the water quality safety defense line
2025-07-15 -
What instrument is used to measure TOC?
2025-07-23 -
Water Quality Ozone Detector: Rapid and Accurate On-Site Ozone Monitoring Solution
2025-09-19 -
Handheld residual chlorine analyzer: a portable guardian of water quality safety
2025-07-15 -
What is a handheld water quality tester for for water quality measurement?
2025-07-23 -
Biological toxicity detector based on bioluminescence sensing technology: principles, advantages and applications
2025-07-23