P

Product Center

Recommended articles

Positioning iconCurrent location:HOME>PRODUCT>COD/BOD Analyzer>BOD Analyzer>BOD Analyzer
BOD Analyzer

BOD Analyzer HM-BOD

【Introduction】Mercury-free differential-pressure BOD measurement with six independent test terminals, a 0–4000 mg/L nominal range and 0.01 mg/L resolution.

Product details

BOD analyzer functional features and mercury-free pressure measurement

BOD measurement applications in wastewater monitoring and laboratories

BOD5 Android touchscreen configuration in the BOD product range

Six independent BOD measurement terminals and culture bottles

Mercury-free differential-pressure BOD measurement illustration

BOD concentration displayed directly on the measurement terminal

BOD analyzer incubation-cycle and data-recording features

BOD analyzer wireless detection heads and stirring platform

BOD analyzer measurement and battery features

HM-BOD and HM-BOD5 model specification comparison

BOD analyzer culture conditions and technical specifications

Product Overview

The HM-BOD from HM Instruments measures biochemical oxygen demand in water using mercury-free differential-pressure sensing during incubation. Six independent measurement terminals support parallel testing and direct display of BOD concentration.

Key Features

  • Six samples can be measured in parallel; independent terminals allow a new measurement group to be started during another test.
  • Direct concentration display and automatic data recording reduce manual result calculation.
  • Program-controlled magnetic stirring supports the incubation procedure.
  • The incubation cycle is adjustable, with up to 60 sampling points per measurement cycle.

Applications

Use for BOD measurement in wastewater-treatment laboratories, discharge monitoring, environmental testing, third-party laboratories, research and teaching. Prepare and incubate the sample using the selected BOD procedure; the listed incubation temperature is 20 ±1 °C.

Technical Specifications

ParameterSpecification
Measurement principleMercury-free differential pressure
Nominal measurement range0–4000 mg/L, direct measurement
Resolution0.01 mg/L
Specified measurement accuracy±8%
Independent measurement terminals6
Sampling pointsUp to 60 per cycle
Culture bottle volume580 mL
Incubation temperature20 ±1 °C
StirringProgram-controlled magnetic stirring
Power supplyAC 220 V ±10%, 50–60 Hz
Dimensions275 × 185 × 305 mm

Operation and Support

Select the measurement range and incubation procedure for the water sample, prepare the culture bottles and maintain the required incubation temperature. Use the independent terminals to organize test groups and review the recorded concentration values after the selected measurement period.

Product Enquiries

Tell our sales representative your sample type, measurement task and configuration needs for product enquiries and coordination of service requests.

Sales Contact: Grace
Email: graceliu@hmdzkj.cn
Tel / WhatsApp / WeChat: +86 17853698681

Article address:https://www.hmwatertesting.cn/cod3/hm-bod-mercury-free-bod-analyzer.html